Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.creatorFigueroa, Rodolfo G.-
dc.creatorSantibañez, Mauricio-
dc.creatorValdes, Cristian-
dc.creatorValente, Mauro Andres-
dc.date2019-03-14T15:02:50Z-
dc.date2019-03-14T15:02:50Z-
dc.date2016-01-
dc.date2019-03-13T17:37:51Z-
dc.date.accessioned2019-04-29T15:51:27Z-
dc.date.available2019-04-29T15:51:27Z-
dc.date.issued2016-01-
dc.identifierFigueroa, Rodolfo G.; Santibañez, Mauricio; Valdes, Cristian; Valente, Mauro Andres; Characterization of hemispherical area X-ray detector based on set of proportional counters with needle anodes; Pergamon-Elsevier Science Ltd; Applied Radiation and Isotopes; 107; 1-2016; 191-194-
dc.identifier0969-8043-
dc.identifierhttp://hdl.handle.net/11336/71619-
dc.identifierCONICET Digital-
dc.identifierCONICET-
dc.identifier.urihttp://rodna.bn.gov.ar:8080/jspui/handle/bnmm/303866-
dc.descriptionThis work introduces a new, versatile and robust X-ray detector with hemispherical 2π geometry, based on a set of 15 small cylindrical proportional counters located in a hexagonal and pentagonal fullerene C60 pattern, at the same distance from the center (where a sample is placed). The counteranode consists of stainless steel sewing needles with spherical tips measuring approximately 80μm in diameter. The space between the counters and the sample could contain air, the same gas as the counters or vacuum. This allows a significant increase in the count rates by a factor approximately equal to the number of counters connected. It is shown that an energy resolution of 20% for 5.9keV photons can be obtained, and a global counting rate of around 106counts/s is achievable by the 15 Needle Anode Proportional Counters (NAPCs) operating in parallel mode, in our setup.-
dc.descriptionFil: Figueroa, Rodolfo G.. Universidad de La Frontera; Chile-
dc.descriptionFil: Santibañez, Mauricio. Universidad de La Frontera; Chile-
dc.descriptionFil: Valdes, Cristian. Centro Oncológico de Antofagasta; Chile-
dc.descriptionFil: Valente, Mauro Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina-
dc.formatapplication/pdf-
dc.formatapplication/pdf-
dc.languageeng-
dc.publisherPergamon-Elsevier Science Ltd-
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0969804315302190-
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.apradiso.2015.10.027-
dc.rightsinfo:eu-repo/semantics/restrictedAccess-
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/-
dc.sourcereponame:CONICET Digital (CONICET)-
dc.sourceinstname:Consejo Nacional de Investigaciones Científicas y Técnicas-
dc.sourceinstacron:CONICET-
dc.subjectGAS PROPORTIONAL COUNTER-
dc.subjectNEEDLES ANODE-
dc.subjectX-RAY DETECTORS-
dc.subjectAstronomía-
dc.subjectCiencias Físicas-
dc.subjectCIENCIAS NATURALES Y EXACTAS-
dc.titleCharacterization of hemispherical area X-ray detector based on set of proportional counters with needle anodes-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.typeinfo:ar-repo/semantics/articulo-
Aparece en las colecciones: CONICET

Ficheros en este ítem:
No hay ficheros asociados a este ítem.