Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.provenanceRIUNNE - Universidad Nacional del Nordeste-
dc.creatorPeláez, Alina Noelia-
dc.creatorPonce, Alejandro Javier-
dc.creatorMazza, Silvia Matilde-
dc.date2013-11-
dc.date.accessioned2020-02-17T15:33:58Z-
dc.date.available2020-02-17T15:33:58Z-
dc.date.issued2013-11-
dc.identifierOdontoestomatología. 2013;15 (22) : 16-23-
dc.identifierhttp://repositorio.unne.edu.ar/handle/123456789/1668-
dc.identifier.urihttp://rodna.bn.gov.ar/jspui/handle/bnmm/576479-
dc.descriptionFil: Peláez, Alina Noelia. Universidad Nacional del Nordeste. Facultad de Odontología; Argentina.-
dc.descriptionFil: Ponce, Alejandro Javier. Universidad Nacional del Nordeste. Facultad de Odontología; Argentina.-
dc.descriptionFil: Mazza, Silvia Matilde. Universidad del Nordeste del Nordeste. Facultad de Odontología; Argentina.-
dc.descriptionComparar los valores obtenidos con sonda milimetrada y compás de punta seca como instrumentos de medida en la aplicación del Índice Estético Dental (DAI). Metodología: En 50 pacientes mayores de 12 años con dentición permanente, del Hospital Odontológico de la Facultad de Odontología de la Universidad Nacional del Nordeste (UNNE), se midieron las variables que componen el DAI, alternando ambos instrumentos de medición y se calculó el DAI. Resultados: En un 86 % de los casos ambos instrumentos arrojaron valores idénticos para las variables del DAI y en el 14 % restante las variaciones no superaron el mm. La correlación entre la puntuación final del DAI, midiendo las variables con sonda milimetrada y con compás de punta seca, fue estadísticamente significativa (r= 0,999). Conclusión: Las variaciones entre las medidas no influyeron en la puntuación final del índice lo que valida a la sonda milimetrada como instrumento de registro para el cálculo del DAI.-
dc.descriptionCompare the values obtained with calibrated probe and with drypoint compass as measuring instrument in implementing the Dental Aesthetic Index (DAI). Methodology: In 50 patients over 12 years with permanent dentition from ofDental Hospital, Faculty of Dentistry UNNE,were measured the variables that built the DAI, alternating both measuring instruments and estimated the DAI. Results: In 86% of cases both instruments yielded identical values for the DAI variables and the remaining 14% did not exceed one mm. The correlation between the final score of the DAI, measuring variables with calibrated probe and drypoint compass, was statistically significant (r = 0.999). Conclusions: Variations between measures not influence the final score of the indexvalidates the calibrated probe as a tool of registration for calculating the DAI.-
dc.formatapplication/pdf-
dc.formatp.16-23-
dc.languagespa-
dc.publisherUniversidad de la República de Uruguay-
dc.relationhttps://www.redalyc.org/comocitar.oa?id=479647722003-
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/ar/-
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Argentina-
dc.source.urihttp://repositorio.unne.edu.ar/handle/123456789/1668-
dc.subjectMaloclusión-
dc.subjectEstética Dental-
dc.subjectOrtodoncia Correctiva-
dc.subjectInstrumentos Dentales-
dc.subjectMalocclusion-
dc.subjectAesthetics- Dental-
dc.subjectCorrective Orthodontics-
dc.subjectDental Instruments-
dc.titleValidación de la sonda milimetrada como instrumento de medida del índice estético dental-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:ar-repo/semantics/artículo-
dc.typeinfo:eu-repo/semantics/publishedVersion-
Aparece en las colecciones: RIUNNE - Universidad Nacional del Nordeste

Ficheros en este ítem:
No hay ficheros asociados a este ítem.